Factory Defaults Settings

The following table identifies factory defaults settings for the MicroMax GPS300, GPS350, and GPS360 interrupters.

To reset the unit's settings using the interrupter's keypad, refer to Resetting to Factory Defaults with Keypad. To reset the unit's settings using Bullhorn Tools, refer to Resetting to Factory Defaults with Bullhorn Tools.

MicroMax Interrupters Factory Defaults Settings

Setting

Value

Interruption

9 programs, Continuous, on/off times in seconds.

Program 1: 3.0 / 1.0

Program 2: 0.8 / 0.2

Program 3: 3.0 / 1.0

Program 4: 4.0 / 1.0

Program 5: 12.0 / 3.0

Program 6: 15.0 / 5.0

Program 7: 0.7 / 0.3

Program 8: 0.8 / 0.2

Program 9: 9.0 / 3.0

Interference

On/off/delay times
in seconds.

On: 13.0s

Off: 5.0s

Delay: 2.0s

Cycle time: 88s

Unit #01/10

Start Time

Immediate

Stop Time

Never

Output Parameters

Switch: Normally Closed

Interruption Cycle: On/Off

UTC Offset

UTC -06

Zero Crossing

Disabled