Charge RM4010, RM4014, RM4014S, RM4011, RM4015, RM4013, and RM4016 Batteries
If you are working with an RM4010, RM4014, RM4014S, RM4011, RM4015, RM4013, or RM4016 unit, complete the following steps to charge the battery using the AC battery charger.
-
Use a small slotted screwdriver to remove two (2) screws on the AC battery charger. Set screws aside for re-installation later.
-
Route the battery charger cable through the liquid tight fitting and toward the battery inside the enclosure.
-
Connect the red and black striped wires to the battery in the following manner:
-
Connect the red wire to the positive (+) terminal on the battery.
-
Connect the red and black striped wire to the negative (–) terminal on the battery.
-
-
Connect the other end of the red and red and black striped wires to the AC battery charger in the following manner:
-
Connect the red wire to the positive (+) terminal on the AC battery charger. Secure wire using one (1) screw set aside earlier.
-
Connect the red and black striped wire to the negative (–) terminal on the AC battery charger. Secure wire using one (1) screw set aside earlier.
-
-
Plug the AC battery charger in a 120 VAC power outlet.
-
The AC battery charger installation is now complete.