RM4010, RM4011, RM4013, RM4014, RM4014S, RM4015, and RM4016 Technical Specifications
The following list includes the technical specifications for the RM4010, RM4011, RM4013, RM4014, RM4014S, RM4015, and RM4016.
-
Environmental conditions:
-
Outdoor use only.
-
Maximum altitude: 3,000 m.
-
Temperature range: -30° C to +70° C.
-
Maximum relative humidity: 95% at 45° C, decreasing linearly to 45% at 70° C.
-
Minimum temperature rating for PCB (printed circuit board): at least 105° C.
-
-
DC Input:
-
Voltage: 10 - 14 V DC.
-
Current: 1.5 A DC max.
-
-
AC Input (requires optional external AC-DC power supply):
-
Voltage: 100 - 240 V AC.
-
Current: 0.15 - 0.3 A AC.
-
Frequency range: 50 - 60 Hz.
-
-
Battery:
-
RM4010: Power Sonic PS-1230, 12 V, 3.4 AH, rechargeable, sealed lead acid battery (American Innovations, Ltd. part number 370042-000). Specified battery shall be used.
-
RM4014/RM4014S: Power Sonic PS-1221S, 12 V, 2.0 AH rechargeable, sealed lead acid battery (American Innovations, Ltd. part number 370149-000). Specified battery shall be used.
-
RM4011/RM4015: Power Sonic PS-1221S, 12 V, 2.0 AH rechargeable, sealed lead acid battery ( American Innovations, Ltd. part number 370149-000). Specified battery shall be used.
-
RM4013/RM4016: 2.4 AH sealed lead acid battery with 1.6 W solar panel. Specified battery shall be used.
-
-
Switch Output — 0-12 V DC; 0.5 A DC max source current.
-
Analog CH1, CH3, and CH4 — ±5 V DC.
-
Analog CH2 — ±100 V DC.
-
Digital CH5 and CH6 — 0 - 15 V DC.
-
Scan Rate (accumulator) — input sampled 16 times per second, with a minimum pulse width of 250 ms.
-
Interconnect cable — Belden 5308UE; 300 Vrms; rated FT4; 600 V - 105° C, or equivalent.
-
Fuse — Cooper Bussmann ATC-3, fast acting, blade type.