Connect Input Wires
Ensure that power to the rectifier has been turned off before wiring the unit.
American Innovations recommends using AI part number 211061-000 (Belden 5308UE), or equivalent, for wiring inputs. Refer to Technical Specifications for the technical specifications for this wiring.
Complete the following steps to connect input wires to the RM4010 , RM4014, or RM4014S.
-
Connect your device(s) to the unit using the information in the following list:
To ensure a clean stable reading, keep field wiring as short as possible and use shielded twisted pair wire such as Alpha 2463C.
-
CH 1: supports analog (±5 VDC).
-
CH 2: supports analog (±100 VDC).
-
CH 3 and CH 4: support analog (±5 VDC).
-
CH 5 and CH 6: support 0 - 15 V DC digital. Channel 5 can also be used as an accumulator.
-
-
Dress input wires inside the unit enclosure.
-
Connect unit input wires to the output terminals of your device(s).
If wires are to be buried or covered, conduit must be used to protect wires.
-
Tighten fitting on the bottom of the unit's enclosure.
-
If your device is turned off, turn ON the device to restore power to field wiring.
-
Continue with Installation Overview to configure the unit for service.