Technical Specifications

The following technical specifications are for the RM1000 Series, including the RM1250 and accessories.

  • Environmental conditions:

    • Indoor or outdoor use

    • Maximum altitude: 3,000 m

    • Temperature range: -30° C to +60° C

    • Units can be used in 100% humidity (rain)

  • Battery ꟷ Specified batteries shall be used - part number 517206-000.

  • Interconnect cable ꟷ Belden 5308UE; 300 Vrms; rated FT4; 600 V - 105° C, or equivalent.

  • Inputs ꟷ two dry contact closure or digital inputs

    • Dry contact:

      • 100 μA source current

      • Maximum cycle rate = 8 cycle/s; minimum state change duration = 62.5 ms

    • Digital input:

      • Accumulates up to a 9-digit reading

      • Minimum Logic 1 = 1 V; maximum Logic 0 = 800 mV

      • Accumulator: maximum rate = 8 count/second

      • Minimum state change duration = 62.5 ms

  • Parts:

    • Included:

      • dome assembly (part number 826552-000)

      • batteries, set of 2 (part number 517206-000):

        • Li-Ion, 7.4 V, 2.0 Ah capacity

        • Lithium, 3.6 V, 13.0 Ah capacity

      • American Innovations USB dongle (part number 626595-000)

  • Optional:

    • flat base adapter (part number 826552-A-KFO00AA)

    • index, 10 cuft (part number 826552-A-KFP00AA)

    • index base adapter (part number 826552-A-KFQ00AA)