Suggested On/Off Settings
On/Off High/Low setup for 1 second cycle |
||
A minimum/maximum reading from a sample of readings. Of the remaining 45 readings, the most negative reading is equal to the on reading and the least negative reading is equal to the off reading. 60 readings per cycle (60 readings per second). |
||
0.7 on 0.3 off 0.8 on 0.2 off |
200 mSec On Delay 150 mSec Off Delay 200 mSec On Delay 100 mSec Off Delay |
Filters out 12 most negative readings Filters out 3 least negative readings Filters out 12 most negative readings Filters out 3 least negative readings |
On/Off High/Low setup for greater than 1 second cycle |
||
A minimum/maximum reading from a sample of readings. Of the remaining 99 readings, the most negative reading is equal to the on reading and the least negative reading is equal to the off reading. 120 readings per cycle (60 readings per second): |
||
1.5 on 0.5 off |
250 mSec On Delay 150 mSec Off Delay |
Filters out 15 most negative readings Filters out 6 least negative readings |
On/Off GPS Sync setup for 1 second cycle |
||
A minimum/maximum reading from a sample of readings. Of the remaining 99 readings, the most negative reading is equal to the on reading and the least negative reading is equal to the off reading. A snapshot of readings in a certain time period: |
||
0.7 on 0.3 off 0.8 on 0.2 off |
200 mSec On Setup 150 mSec Off Delay 200 mSec On Setup 100 mSec Off Delay |
Takes reading 200 mSec before the on > offtransition. Takes reading 150 mSec after the on > offtransition. Takes reading 200 mSec before the on > offtransition. Takes reading 100 mSec after the on > offtransition. |
On/Off setup for greater than 1 second cycle |
||
A minimum/maximum reading from a sample of readings. Of the remaining 45 readings, the most negative reading is equal to the on reading and the least negative reading is equal to the off reading. |
||
1.5 on 0.5 off |
250 mSec On Setup 250 mSec Off Delay |
Takes reading 200 mSec before the on > offtransition. Takes reading 150 mSec after the on > offtransition. |
On/Off GPS Real-time setup for greater than 2-second cycle |
||
8.0 on 2.0 off |
200 mSec On Delay 250 mSec Off Delay |
Starts capturing readings 200 mSec after the on > off transition. Starts capturing readings 250 mSec after the on > off transition. |
GPS-RT |
50 mSec |
No readings 50 mSec before off cycle to Off Delay. No readings 50 mSec before on cycle to On Delay. |
GPS Real Time delay |
||
Does not capture any reading for 50 mSec before either the on > off or the off > on transition. Recommended GPS-RT Setup Time is 50 mSec for Mercury switches and 30 mSec for solid state switches. |