Set DCVG Survey Properties
To set the properties for the current DCVG survey, tap File > Properties to display the properties window for the current survey.
DCVG Survey Module - Survey Menu
DCVG Survey Module - Properties Menu
These property settings include the following:
-
Properties— segment, date, pipe, tech, run, and other values for the survey.
-
Direction — how you can move from record to record, either Ascending or Descending.
-
Mode — Fixed Increment or Flagged.
-
Metric: option to set distances in metric values.
-
Monitor Record Count Per Flag: option for Flagged mode only.
-
-
-
On/Off High/Low: for an interrupted survey using non-GPS synchronized interrupters. An On/Off High/low survey will sample 60 times per second and discard the most negative and least negative values in a cycle based on the On/Off Delays. Of the remaining values in the cycle, the most negative value will be on reading and the least negative value will be the off reading.
-
On/Off GPS Sync: for an interrupted survey using GPS synchronized interrupter with shorter on and off intervals.
-
Cycle Begins With sets when the cycle begins (either On or Off) for On/Off GPS Sync or On/Off GPS RT methods.
-
-
GPS — record GPS location, record time of reading, and show message when GPS is lost.